Oxygen Analyzer Calibration in Singapore for IG and N₂ Systems

On-board calibration of fixed and portable oxygen analysers on tankers and gas carriers in Singapore. We check zero and span with certified gases, test the 5% high-oxygen alarm and recorder, and issue a certificate with as-found and as-left readings.

  • ISO 9001:2015
  • ISO 45001:2018
  • bizSAFE Level 4
  • bizSAFE Star
  • Alongside & anchorage
  • O₂ span gases in stock
Marine engineer at a Singapore port preparing for oxygen analyser calibration on a tanker
IG · IGG · N₂ · portableZirconia, paramagnetic and galvanic O₂ sensors

Oxygen analyzer calibration in Singapore, in short: Alright Engineering Solutions (AES) calibrates the oxygen analysers on inert gas plants, inert gas generators and nitrogen generators, plus portable O₂ meters, on ships in Singapore. We record the as-found reading, check the sample system, set zero and span with certified gases, prove the high-oxygen alarm and recorder, and leave a certificate on board.

Scope

Oxygen Analysers We Calibrate On Board

Every reading that decides whether a tank is safely inerted comes from one of these. They all need the same care: clean sample, right gases, proven alarms.

Flue gas IG plant analysers

Fixed O₂ analysers on the inert gas main of boiler flue gas IG systems, with continuous indication and recording.

Inert gas generators (IGG)

O₂ analysers on oil-fired inert gas generators, checked against the 5% limit before gas goes to the tanks.

Nitrogen generators

Purity analysers on N₂ generators used on chemical tankers and gas carriers, where the O₂ reading decides product quality and tank safety.

Low-oxygen space monitors

Fixed O₂ depletion monitors in spaces where inert gas or nitrogen could leak, with the low-oxygen alarm checked.

Zero & span gases

O₂-in-N₂ span gases and high-purity nitrogen zero gas supplied in Singapore, so your crew can check between visits.

O₂ calibration gases →
Sensor types

Zirconia, Paramagnetic or Galvanic: How Each Is Calibrated

The sensor decides which gases we use and what can go wrong. Tell us the model and we'll bring the right set. For the full background, read our guide to oxygen analyser calibration for inert gas systems.

SensorWhere you'll find itCalibration approachTypical issue
ZirconiaFlue gas IG plants and IG generatorsLow-range O₂ span gas plus air or a second reference, per the maker's procedureCell ageing, heater faults, contamination from soot and SO₂
ParamagneticFixed IG and N₂ analysersZero with high-purity nitrogen, span with a certified O₂ gasSensitive to vibration, moisture and sample flow changes
Galvanic / electrochemicalPortable O₂ meters, N₂ generators, space monitorsZero with nitrogen, span with certified O₂ gas or clean airSensor slowly consumed, so readings fade with age
FSS Code Chapter 15

The 5% Limit Only Works If the Analyser Is Right

Under the FSS Code chapter on inert gas systems, the system must deliver inert gas with no more than 5% oxygen by volume. The oxygen content has to be continuously indicated and permanently recorded while inert gas is supplied, with an audible and visual alarm when it goes above 5%. Suitable means must also be provided to zero and span calibrate both fixed and portable gas measuring instruments, using zero and span gases.

  • An analyser reading 1% low can show 4.8% while the gas going to your tanks is nearer 6%
  • Cargo tanks are kept at 8% oxygen or below, and portable meters are how you confirm it
  • Spaces where inert gas could leak need a low-oxygen alarm, set below 19%
  • The recorder has to work too. A gap in the O₂ record raises questions at inspection.

Need the gases for onboard checks? We supply O₂ span gases and 99.995% nitrogen zero gas in Singapore.

How it works

How We Calibrate an IG Oxygen Analyser On Board

Most bad O₂ readings start in the sample line, not the sensor. So that's where we start.

  1. As-found reading

    We record what the analyser shows on the reference gases before touching anything.

  2. Sample system check

    Filters, water trap, bubbler, sample pump and flow are checked. Leaks that pull in air make the reading high.

  3. Zero

    Zero is set with high-purity nitrogen, or the maker's low-range gas for zirconia cells.

  4. Span

    Span is set with a certified O₂-in-N₂ gas close to the working range, then checked at a second point.

  5. Alarm & recorder

    We prove the 5% high-oxygen alarm and any IG shutdown or vent action, and check the recorder is logging.

  6. Certificate

    As-left readings, gases used and alarm results go on the certificate, and the analyser is labelled.

Cargo operations coming up? Send your port window and we'll fit the job around it.

Common problems

Why IG Oxygen Analysers Read Wrong

  • Water carry-over. Wet filters from the scrubber or bubbler reach the sensor and upset the reading.
  • Air leaking into the sample line. A loose fitting or worn sample pump pulls in air, so O₂ reads high and the plant keeps venting.
  • Blocked sample lines. Soot and scale slow the response, so the alarm comes late.
  • Ageing sensors. Galvanic cells are used up over time and zirconia cells lose output.
  • Wrong or expired span gas. Calibrating on the wrong cylinder bakes the error in.
  • Recorder not logging. The analyser works, but the permanent record has gaps.

We've traced a similar sample pump leak on a fixed gas sampling system. Read the Consilium SW2020 analyser pump leakage case study.

Engineer checking an oxygen analyser with calibration gas on board a tanker
Documentation

What's on Your Oxygen Analyser Calibration Certificate

  • Analyser make, model, serial number and range
  • Zero and span gases used, with concentration, lot number and expiry
  • As-found and as-left readings at each gas
  • High-oxygen alarm set point and test result
  • Sample system condition and parts replaced
  • Date, vessel, next due date and engineer's signature

Booking checklist — send us these

  • Vessel name, IMO number and ship type
  • IG plant, IGG or N₂ generator type
  • Analyser make, model and range
  • Berth or anchorage, ETA and ETD
  • Photo of the last calibration certificate
Send via Contact Form
Ship officer reviewing an oxygen analyser calibration certificate
Makes & models

Oxygen Analyser Makes We're Asked About Most

Send your make and model number and we'll confirm the method and gases before we book.

  • Servomex
  • Yokogawa
  • Daiichi Nekken
  • Green Instruments
  • Portable O₂ meters: Riken Keiki, MSA, Honeywell BW
Why AES

Why Tanker Operators Use AES for O₂ Analyser Calibration

We bring the gases

Certified O₂-in-N₂ span gases and high-purity nitrogen, matched to your analyser's range.

Whole system, not just the sensor

Sample line, filters, pump, alarm and recorder, because that's where most faults hide.

Certified management systems

ISO 9001:2015 and ISO 45001:2018, bizSAFE Level 4 completed and bizSAFE Star.

Alongside and at anchorage

Planned around your port stay and cargo operations.

See all our marine calibration services in Singapore.

FAQ

Oxygen Analyzer Calibration in Singapore: Common Questions

How often should an IG oxygen analyser be calibrated?

Follow the maker's manual and your safety management system. Many makers recommend frequent span checks by the crew, weekly or monthly depending on the model, with a full calibration and service at longer intervals. Our calibration interval table gives common intervals.

What gases do you use to calibrate an oxygen analyser?

Usually high-purity nitrogen for zero and a certified O₂-in-N₂ mixture for span, chosen to suit the analyser's range. Zirconia analysers follow the maker's own gas procedure.

Can my crew calibrate the analyser between your visits?

Yes, and they should, following the maker's manual. We can supply the zero and span gases and regulators in Singapore so the onboard checks are done properly.

Do you calibrate nitrogen generator O₂ analysers?

Yes. N₂ generator purity analysers are calibrated the same way, with gases chosen for the low O₂ range they read.

Can you calibrate at Singapore anchorage?

Yes. We attend ships at anchorage as well as alongside at terminals and shipyards. Your agent usually arranges the launch.

Why does my O₂ analyser read high even after calibration?

Often it's air getting into the sample line through a leak or a worn sample pump. We check the sample system before calibrating for exactly this reason.

How much does oxygen analyser calibration cost?

It depends on the system, analyser model and location. Send the details via the contact form or WhatsApp and we'll price it before we board.

Inerting before your next cargo?

Get Your Oxygen Analysers Calibrated in Singapore

Send the vessel details and analyser model. We'll confirm gases, timing and price, then attend alongside or at anchorage.