UTI Meter & Tank Gauging Calibration in Singapore

Calibration, repair and certification for portable UTI meters and tank gauging equipment on tankers calling Singapore. We check ullage, temperature and oil/water interface against certified references and turn the job around within your port stay.

  • ISO 9001:2015
  • ISO 45001:2018
  • bizSAFE Level 4
  • bizSAFE Star
  • MMC · HERMetic · Tanktech
  • Calibration certificate issued
Portable UTI meter for ullage, temperature and interface gauging on tankers in Singapore
Ullage · Temperature · InterfaceEvery function checked before the certificate is signed

UTI meter calibration in Singapore, in short: Alright Engineering Solutions (AES) cleans, tests, repairs and calibrates portable UTI meters and tank gauging equipment for tankers in Singapore. Each unit's tape length, temperature sensor, oil/water interface detection and earthing continuity are checked against certified references, and you get a calibration certificate with the readings recorded.

Scope

UTI Meters and Tank Gauging Equipment We Calibrate

From the chief officer's portable UTI to the fixed gauging in the cargo control room, the numbers behind your ullage report need a calibration trail.

Portable UTI meters

Ullage, temperature and interface tapes used for cargo gauging and custody transfer, including open and closed gauging models.

UTI meters we supply →

Closed & restricted gauging

Vapour-lock UTI meters for inerted and toxic cargoes, checked so readings stay accurate without opening the tank.

Interface detectors & tapes

Oil/water interface detectors and gauging tapes, including conductivity electrode and audible signal checks.

Fixed tank gauging systems

Level gauges and temperature sensors on fixed cargo tank gauging, including Enraf systems, checked against manual readings.

Temperature probes

Tape and fixed-system temperature sensors checked at several points against a certified master thermometer.

Repairs & spares

Replacement tapes, sensors, display boards and winding parts. When a unit can't be saved, we supply a replacement UTI in Singapore.

Inside the calibration

What Gets Checked During UTI Calibration

A UTI meter does three jobs. A certificate that only covers one of them leaves your cargo figures exposed.

Check How it's done Why it matters
Tape length Compared with a certified reference tape along its length Ullage error goes straight into the cargo volume. API MPMS 3.1A sets ±2 mm over 0–30 m for working tapes.
Temperature Sensor head in a thermal bath beside an ISO/IEC 17025 certified master thermometer, at several points, typically 25–65°C Temperature drives the volume correction factor on every tank
Oil/water interface Conductivity electrode and tone checked: continuous for oil, intermittent for water A misread interface means wrong free-water figures and B/L disputes
Ullage sensor Liquid level detection checked for correct, repeatable response Corroded sensors on chemical and crude tankers give late or false signals
Earthing continuity Inner wire and earthing clamp tested end to end The UTI must be earthed before it goes into a tank, to avoid static discharge
Electronics & seals Display, audio signal, battery and vapour-lock seals checked A failed beep or leaking seal makes a sound unit unusable
Cargo figures

Why a Drifting UTI Costs More Than the Calibration

API MPMS Chapter 3.1A, the standard practice for manual tank gauging, calls for portable electronic gauges to be verified when new and at least annually after that, against a reference tape traceable to a national standard. That's the minimum. Heavy use, chemical cargoes and rough handling all shorten it.

  • A temperature error of 1°C shifts the corrected volume by roughly 0.1% on many crude grades. On a 100,000 m³ cargo, that's around 100 m³.
  • Ullage and interface errors feed straight into ship's figures and Bill of Lading quantities.
  • Terminal surveyors and oil-major vetting inspectors ask for the UTI calibration certificate. See our SIRE 2.0 calibration checklist.

Want the full picture of what goes wrong inside a UTI? Read our UTI meter service and repair guide.

How it works

Our UTI Calibration and Repair Process

The same sequence, in the same order, every time. Skip a step and the certificate stops meaning anything.

  1. Send the details

    Vessel, make, model, serial numbers and how many units. Tell us your ETA and ETD so we can plan around the port stay.

  2. Decontamination

    Crude, aromatic or chemical residue is cleaned off with solvents before any measurement is trusted.

  3. Function test

    Display, battery and audio signals are checked, including the oil and water tones at the interface.

  4. Temperature check

    Multi-point comparison against a certified master thermometer in a thermal bath.

  5. Tape & earthing

    Tape length against a reference tape, plus earthing wire continuity end to end. Damaged tapes are replaced.

  6. Certificate & return

    Readings go on the certificate, the unit is labelled, and it's returned to the vessel before departure.

Short port stay? Message us your ETA and we'll plan the turnaround.

Common problems

UTI Meter Faults We Repair Most Often

Calibration is only half the job. The other half is fixing what the crew has been working around.

Kinked or worn tapes

Rough handling twists and crimps the tape, and the scale can't be trusted after that.

Corroded level sensor

Aggressive cargoes eat into the ullage sensor, giving late or false liquid signals.

Temperature drift

The probe still reads, just not correctly. Only a bath comparison shows it.

Faulty interface electrode

The conductivity electrode stops telling oil from water reliably.

Dead beep or display

A failed audio signal or PCB display board makes a mechanically sound unit useless.

Broken earthing path

A broken inner wire or clamp means the unit can't be safely earthed before gauging.

Documentation

What's on Your UTI Calibration Certificate

  • Make, model and serial number of the UTI or gauging system
  • Reference tape and master thermometer used, with their certificate details
  • Temperature readings at each test point, against the reference
  • Tape length, interface and earthing continuity results
  • Repairs carried out and parts replaced
  • Calibration date, next due date and the engineer's signature

See what inspectors check on certificates in our guide to marine calibration certificates.

Booking checklist — send us these

  • Vessel name and IMO number
  • UTI make, model, serial and number of units
  • Fixed gauging system make, if included
  • Berth or anchorage, ETA and ETD
  • Photo of the last calibration certificate
Send via Quote Form
Chief officer reviewing a UTI meter calibration certificate before cargo gauging
Makes & models

UTI and Tank Gauging Brands We Work With

We calibrate and repair the UTI meters most common on tankers trading through Singapore. Send your model number and we'll confirm before you book.

  • MMC UTI meters
  • Honeywell HERMetic UTImeter Gtex / Rtex
  • Tanktech
  • Enraf tank gauging
  • Restricted-type interface detectors

Replacing a unit? Browse our portable gauging and UTI meters.

Restricted-type portable UTI and oil/water interface detector
Why AES

Why Tanker Operators Use AES for UTI Calibration

Repair and calibration together

We fix the tape, sensor or board first, then calibrate, so you don't get a certificate for a unit that still misbehaves.

Certified references

Temperature compared against an ISO/IEC 17025 certified master thermometer, tapes against a reference tape.

Certified management systems

ISO 9001:2015 and ISO 45001:2018, bizSAFE Level 4 completed and bizSAFE Star.

Built around port stays

We plan the job to your ETA and ETD so the UTI is back on board before cargo work.

Spares in Singapore

Tapes, sensors and replacement UTI meters supplied locally when a repair isn't worth it.

See all our marine calibration services in Singapore.

FAQ

UTI Meter Calibration in Singapore: Common Questions

How often should a UTI meter be calibrated?

API MPMS Chapter 3.1A calls for portable electronic gauges to be verified when new and at least annually. Many operators and makers set the same yearly interval, with extra checks after damage or repair. See our calibration interval table.

Can you calibrate UTI meters during a short port stay?

Yes, that's how most jobs run. Send your ETA, ETD and number of units in advance and we'll plan the work so the meters are back on board before you sail.

Do you repair UTI meters as well as calibrate them?

Yes. We replace damaged tapes, sensors, display boards and winding parts, then calibrate. If the unit isn't worth repairing, we can supply a replacement.

Which UTI brands do you calibrate?

We work with MMC, Honeywell HERMetic and Tanktech UTI meters, plus restricted-type interface detectors and Enraf tank gauging. Send your model number to confirm.

What temperatures are checked during calibration?

The probe is compared with a certified master thermometer at several points, typically between 25°C and 65°C, covering the range most cargoes are gauged at.

Do you calibrate fixed tank gauging systems too?

Yes. Fixed level and temperature gauging can be checked against manual UTI readings during the same port call. Tell us the system make when you book.

How much does UTI calibration cost in Singapore?

It depends on the model, the number of units and any repairs needed. Send the details via the quote form or WhatsApp and we'll price it before work starts.

Loading or discharging soon?

Get Your UTI Meters Calibrated Before Cargo Work

Send the vessel details, UTI models and port window. We'll confirm timing and price, then get your gauging equipment back on board certified.