Control Bulk Unit Graviner Mark5 Oil Mist Detector

The Graviner MK5 measures the oil mist density in a diesel engine’s crankcase. The MK5 will sound an alarm if the density is higher than a predetermined limit.

Graviner Oil Mist Detector is very successful unit and it is using by hundreds of ships.

Graviner Mark 5 model has a sample pipe system for collecting oil mist from the crankcase. Additionally, it has a display and controls panel that shows the density of the oil mist and lets the user choose and test various functions.

Kidde Graviner Oil Mist Detector has been in use Since the first potential hazard was discovered some fifty years ago, The Graviner MK5 monitors the density of oil mist in a diesel engine’s crankcase to avoid any risk of exploitation.

Product Specifications

Type Parameter
Height
  • 318mm (12.5 In.)
Width
  • 608mm (24 In.)
Depth
  • 191mm (7.5 In.)
Including Anti Vibration Mountings
  • 233mm (9.2 In.)
Weight
  • 28 Kg (61.5 Lb.)
Selectable From
  • 115V 50Hz
  • 115V 60Hz
  • 220V 50Hz
  • 220V 60Hz
  • 230V 50Hz
  • 230V 60Hz
  • 240V 50Hz
  • 240V 60Hz
Power Consumption
  • 70W (Approx).
Air Supply Pressure
  • 1 Bar T 20% (12-18 P.S.I.) Inlet Internally Threaded £ B.S.F
Air Consumption (Dry Air)
  • 6 Litres/Hour
Suction Pressure (Water Gauge) (Sample Port Measured Against Atmosphere)
  • 12mm (0.5 In.)
Number Of Sampling Inlets
  • 4 To 10 (Selectable)
Time Per Sample
  • 1 Second
17mm Inside Diameter 19mm Outside Diameter
  • 17mm Inside Diameter <19mm Outside Diameter
Maximum Distance Between Oil Mist Detector And Sample Point
  • 15M (48ft) For 18mm Inside Diameter 7.5M (24ft) For 14mm Inside Diameter.
Detector Outlet Connection
  • 45mm Inside Diameter. 48mm Outside Diameter. 10M (33ft) Maximum Length.
Displays On Oil Mist Detector:
  • System On Lamp Percentage Of Alarm Level. Sample Number Being Sampled. Simulation Mode Lamp Test Mode Lamp Average Alarm Lamp Deviation Alarm Lamp Flow Fault Lamp Optical Fault Lamp
System Signal Outputs:
  • Fault Alarm : 1 Set Volt Fr Change Over Contacts Main Alarm: 2 Sets Volt Fr Change Over Contacts Engine Slowdown: 1 Set Vc Free Change Over Contacts.