OWS 15ppm Bilge Alarm OMD-2008 EV FC MCU with Flow Control

The OMD-2008 EV FC MCU is equipped with a Flow Sensor. The Flow Sensor is positioned in the Drain line of the Measuring Cell.

If the flow rate through the Measuring Cell is too low, or if the sample is not flowing at all, the Instrument will go to Alarm condition and issue a “Status: Flow?” message. According to MEPC.107(49) the 15ppm Bilge Alarm has to be provided with a representative sample, i.e. the operator of the instrument is responsible to maintain a proper sample flow through the instrument. The recommended sample flow rate for Deckma instruments is approx. 2 Liters per Minute. At this flow rate, with a common setup of separator and 15ppm Bilge Alarm, it is easily possible to reliably operate the instrument, and to ensure the required short reaction time to changes in the oil content of the effluent water.

Product Specifications

Type Parameter
Range:
  • 0 – 30 ppm, Trend indication 50 ppm
Accuracy:
  • According IMO MEPC. 107(49)
Linearity:
  • Up to 30 ppm better than ± 2 %
Display:
  • Yellow Graphic Display
Power Supply:
  • 24 V - 240V AC or DC, Automatic Voltage selection
Consumption:
  • < 10 VA
Alarm Points 1 + 2:
  • Adjustable between 1 - 15 ppm (Works adjustment 15 ppm)
Alarm 1 Operating Delay:
  • (for annunciation purpose) Adjustable between 1 – 540 sec. (Works adjustment 2 sec)
Alarm 2 Operating Delay:
  • (for control purposes) Adjustable between 1 – 10 sec. (Works adjustment 10 sec)
System Fault Alarm:
  • Red LED
Alarm Contact Rating:
  • Potential free 1 pole change over contacts, 3 A / 240 V
Alarm Indication:
  • Red LEDs
Output Signal:
  • 0 – 20 mA or 4 – 20 mA selectable active current loop, ext. Load < 150 Ω
Clean Water Pressure:
  • 0-6 bar
Sample Water Pressure:
  • 0,1 – 6 bar
Sample Flow:
  • Approx. 0,6 - 3 l/min depend. on pressure
Ambient Temperature:
  • 1 to + 55° C
Sample Water Temperature:
  • 1 to + 65° C
Roll:
  • Up to 45°
Size (Computer Unit):
  • 200 mm W x 200 mm H x 100 mm D
Size (EV-FC-MCU+ Measuring Cell):
  • 150 mm W x 290 mm H x 140 mm D
Distance (Computer Unit to Measuring Cell):
  • Distance (Computer Unit to Measuring Cell):
Degree of Protection:
  • IP 65
Weight:
  • 5,9 kg
Pipe Connections:
  • Tube Fittings for 6 mm Tube OD